POWER LIGHT

OPC LIGHT

ERROR TYPE

REPAIR

-

-

AC Power failure

Loose connection, Power Unit or Main Unit

1(1/sec)

-

Lamp Failure

Loose connection to Inverters, reload firmware, Inverter Unit or LCD Panel

2X

-

Power Failure

Inverter Unit or LCD Panel

2X

1X

13V/UR10V failure

Power Unit or Main Unit

2X

2X

3.3V Main Failure

Power Unit or Main Unit

2X

3X

UR6V failure

Power Unit or Main Unit

2X

5X

Panel 5V failure

LCD Control Unit or LCD Panel

2X

7X

CPU Communication

Main Unit or LCD Controller

2X

7X

Audio Amp Error

Loose/Damaged speaker wires, Terminal Unit

2X

8X

LCD Control ROM Error

Main Unit or LCD Control Unit

3X

1X

Communication

Main Unit

3X

2X

Main Failure

Main Unit or LCD Control Unit

3X

3X

Communication

Main Unit

4X

-

Vsync Error

Reseat cables, Main Unit

5X

-

Monitor Temp Failure2

Main Unit

6X

-

BD Unit Error

BD Unit

8X

-

Flash Rom Error

Main unit or reload firmware

 

*************************************